Aggregate Source Approval Report |
Owner: Manke Lumber Co. | Aggregate Source: PS-B-348 |
Lessee: Mountain Stone Aggregate LLC | Known as: C and V Roy Pit |
Located in: . Section 3 T17N R02E | County: Pierce |
Remarks:
Mineral Agg. and Surfacing: Test Date: 03/28/2022 Expiration Date: 03/28/2027
Absorption: 1.35 | Apparent Sp. G.: 2.761 | Bulk Sp. G. (SSD): 2.698 | Bulk Sp. G.: 2.662 |
Deg: 63 | LA: 18 |
Remarks:  
Currently Approved for:
ATB | Ballast | BST Crushed Cover Stone |
BST Crushed Screenings | Crushed Surfacing Base Course | Crushed Surfacing Key Stone |
Crushed Surfacing Top Course | Gravel Backfill for Foundation Class A | HMA Other Courses |
HMA Wearing Course | Maintenance Rock | Permeable Ballast |
Acceptance tests need to be performed as necessary.
Aggregates for Concrete: Test Date: 06/17/2021 Expiration Date: 06/17/2026
ASR - 14 Day : 0.53 | ASR - One Year: | CCA Absorption: 1.1 | CCA Sp.G: 2.694 |
Deg: 72 | FCA Absorption: 2.23 | FCA Organics: 3 | FCA Sp. G: 2.62 |
LA: 11 |
Remarks:  
Currently Approved for:
Coarse Concrete Aggregates (Other as defined in 6-02.3(2)) |
Fine Concrete Aggregates |
Coarse Concrete Agg (Structural and Paving Concrete) |
Riprap, Quarry Spalls, Rock for Rock Wall, Erosion and Scour Protection: Test Date: Expiration Date:
Absorption: | Apparent Sp. G.: | Bulk Sp. G. (SSD): | Bulk Sp. G.: |
Deg: | LA: |
Remarks:  
NOT Approved for:
Quarry Spalls | Riprap | Rock for Erosion and Scour Protection |
Rock for Rock Walls | Stone 9-27.3(6) |
Streambed Aggregates: Test Date: 03/28/2022 Expiration Date: 03/28/2027
Absorption: 1.35 | Apparent Sp. G.: 2.761 | Bulk Sp. G. (SSD): 2.698 | Bulk Sp. G.: 2.662 |
Deg: 63 | LA: 18 |
Remarks:  
Currently Approved for:
Streambed Aggregate |
Gravel Borrow for Structural Earth Walls: Test Date: 03/28/2022 Expiration Date: 03/28/2027
Bulk Sp. G. (SSD): 2.698 | Deg: 63 | LA: 18 |
Remarks: For geosynthetic reinforcement, the gravel borrow shall be tested for pH prior to placement. For metallic reinforcement, the gravel borrow shall be tested for pH, resistivity, chlorides, and sulfates prior to placement. If the resistivity of the backfill material equals or exceeds 5,000 ohm-cm, the specified chloride and sulfate limits may be waived. If the aggregate source has variable quality, additional testing may be required. Contact the Regional Materials Engineer or the State Geotechnical Engineer for direction.  
Currently Approved for:
Gravel Borrow for Str Earth Walls |
ALL OTHER PIT RUN MATERIALS:
Project Engineer may request preliminary samples but Aggregate Source Approval is not required.
AGGREGATE MATERIALS NOT REQUIRING ASA APPROVAL :
Aggregate for Gravel Base 9-03.10
Gravel Backfill for Foundation Class B 9-03.12(1)B
Gravel Backfill for Walls 9-03.12(2)
Gravel Backfill for Pipe Zone Bedding 9-03.12(3)
Gravel Backfill for Drains 9-03.12(4)
Gravel Backfill for Drywells 9-03.12(5)
Backfill for Sand Drains 9-03.13
Sand Drainage Blanket 9-03.13(1)
Gravel Borrow 9-03.14(1)
Select Borrow 9-03.14(2)
Common Borrow 9-03.14(3)
Native Material for Trench Backfill 9-03.15
Foundation Material Class A and B 9-03.17
Foundation Material Class C 9-03.18
Bank Run Gravel for Trench Backfill 9-03.19
Commercial Concrete Aggregate 6-02.3(2)B