Design - General Special Provisions

text size: T T T

Index: General Special Provisions Division 7

Design: Project DevelopmentGSP & Amendments |  Division 7

DIVISION7.GR7 DRAINAGE STRUCTURES, STORM SEWERS, SANITARY SEWERS. WATER MAINS, AND CONDUITS 02.GR7 CULVERTS 0202.GR7 Materials 020202.GR7 Precast Reinf. Conc. Box Culvert (April 2, 2007) Use in projects with concrete box culverts constructed with four sided monolithic precast concrete elements. Include with 020301.GR7, 020401.FR7, and 020501.GR7. 020203.GR7 Precast Reinf. Conc. Split Box Culvert (April 2, 2007) Use in projects with concrete box culverts constructed with U shaped precast concrete base elements and precast concrete lid panels. Include with 020302.GR7, 020402.FR7, and 020502.GR7. 0203.GR7 Construction Requirements 020301.GR7 Precast Reinf. Conc. Box Culvert (April 2, 2007) Use in projects with concrete box culverts constructed with four sided monolithic precast concrete elements. Include with 020202.GR7, 020401.FR7, and 020501.GR7. 020302.GR7 Precast Reinf. Conc. Split Box Culvert (April 2, 2007) Use in projects with concrete box culverts constructed with U shaped precast concrete base elements and precast concrete lid panels. Include with 020203.GR7, 020402.FR7, and 020502.GR7 0204.GR7 Measurement 020401.FR7 Precast Reinf. Conc. Box Culvert (April 2, 2007) Use in projects with concrete box culverts constructed with four sided monolithic precast concrete elements. The fill-in itemizes the approximate quantities for the components and work included in the lump sum bid item. For projects with more than one precast reinforced concrete box culvert, the itemized list may be repeated for each structure as necessary. Include with 020202.GR7, 020301.GR7, and 020502.GR7. 1 fill-in. 020402.FR7 Precast Reinf. Conc. Split Box Culvert (April 2, 2007) Use in projects with concrete box culverts constructed with U shaped precast concrete base elements and precast concrete lid panels. The fill-in itemizes the approximate quantities for the components and work included in the lump sum bid item. For projects with more than one precast reinforced concrete split box culvert, the itemized list may be repeated for each structure as necessary. Include with 020203.GR7, 020302.GR7, and 020502.GR7. 1 fill-in. 0205.GR7 Payment 020501.GR7 Precast Reinf. Conc. Box Culvert (April 2, 2007) Use in projects with concrete box culverts constructed with four sided monolithic precast concrete elements. Include with 020202.GR7, 020301.FR7, and 020401.GR7. 020502.GR7 Precast Reinf. Conc. Split Box Culvert (April 2, 2007) Use in projects with concrete box culverts constructed with U shaped precast concrete base elements and precast concrete lid panels. Include with 020202.GR7, 020303.FR7, and 020402.GR7 05.GR7 MANHOLES, INLETS, CATCH BASINS, AND DRYWELLS 0502.GR7 Materials 050216.GR7 Grate Inlets And Drop Inlets 0502161.GR7 (Grate B required on grate inlets) (December 4, 2006) The Contractor shall furnish and install Grate B, as shown on the Standard Plans on all grate inlets.