Design: Project Development | GSP & Amendments | Division 7
DIVISION7.GR7 DRAINAGE STRUCTURES, STORM SEWERS, SANITARY
SEWERS. WATER MAINS, AND CONDUITS
02.GR7 CULVERTS
0202.GR7 Materials
020202.GR7 Precast Reinf. Conc. Box Culvert
(April 2, 2007)
Use in projects with concrete box culverts constructed
with four sided monolithic precast concrete elements.
Include with 020301.GR7, 020401.FR7, and 020501.GR7.
020203.GR7 Precast Reinf. Conc. Split Box Culvert
(April 2, 2007)
Use in projects with concrete box culverts constructed
with U shaped precast concrete base elements and precast
concrete lid panels. Include with 020302.GR7,
020402.FR7, and 020502.GR7.
0203.GR7 Construction Requirements
020301.GR7 Precast Reinf. Conc. Box Culvert
(April 2, 2007)
Use in projects with concrete box culverts constructed
with four sided monolithic precast concrete elements.
Include with 020202.GR7, 020401.FR7, and 020501.GR7.
020302.GR7 Precast Reinf. Conc. Split Box Culvert
(April 2, 2007)
Use in projects with concrete box culverts constructed
with U shaped precast concrete base elements and precast
concrete lid panels. Include with 020203.GR7,
020402.FR7, and 020502.GR7
0204.GR7 Measurement
020401.FR7 Precast Reinf. Conc. Box Culvert
(April 2, 2007)
Use in projects with concrete box culverts constructed
with four sided monolithic precast concrete elements.
The fill-in itemizes the approximate quantities for the
components and work included in the lump sum bid item.
For projects with more than one precast reinforced
concrete box culvert, the itemized list may be repeated
for each structure as necessary.
Include with 020202.GR7, 020301.GR7, and 020502.GR7.
1 fill-in.
020402.FR7 Precast Reinf. Conc. Split Box Culvert
(April 2, 2007)
Use in projects with concrete box culverts constructed
with U shaped precast concrete base elements and precast
concrete lid panels. The fill-in itemizes the approximate
quantities for the components and work included in the
lump sum bid item. For projects with more than one precast
reinforced concrete split box culvert, the itemized list
may be repeated for each structure as necessary.
Include with 020203.GR7, 020302.GR7, and 020502.GR7.
1 fill-in.
0205.GR7 Payment
020501.GR7 Precast Reinf. Conc. Box Culvert
(April 2, 2007)
Use in projects with concrete box culverts constructed
with four sided monolithic precast concrete elements.
Include with 020202.GR7, 020301.FR7, and 020401.GR7.
020502.GR7 Precast Reinf. Conc. Split Box Culvert
(April 2, 2007)
Use in projects with concrete box culverts constructed
with U shaped precast concrete base elements and precast
concrete lid panels. Include with 020202.GR7,
020303.FR7, and 020402.GR7
05.GR7 MANHOLES, INLETS, CATCH BASINS, AND DRYWELLS
0502.GR7 Materials
050216.GR7 Grate Inlets And Drop Inlets
0502161.GR7 (Grate B required on grate inlets)
(December 4, 2006)
The Contractor shall furnish and install Grate B, as shown
on the Standard Plans on all grate inlets.